GLEDHILL BOILERMATE IS DESIGNED TO PROVIDE IMPROVED SPACE HEATING [ RADIATORS] AND HOT WATER AT MAINS PRESSURE WHEN CONNECTED TO A REMOTELY SITED BOILER[ USUALLY IN THE KITCHEN / GARAGE/ UTILLITY ROOM.

THE GLEDHILL BOILERMATE 2000 ALSO HAS AN OPTION OF "SWITCH" WHICH IS A 9KW ELECTRICAL BACK UP SHOULD THE MAIN BOILER FAIL. STILL WORKING ON THE SAME PRINCIPAL AS A THERMAL STORE.

AGAIN COMMON FAULTS I HAVE SEEN ARE

1. DEFECTIVE STORE SENSOR

2. DEFECTIVE A.C.B. [ APPLIANCE CONTROL BOARD]

3.PHE [ PLATE HEAT EXCHANGER] SENSOR

4. JAMMED OR SEIZED PUMPS.

5. EARLY BOILERMATE MODELS ARE PRONE TO LEAKING AROUND PUMP VALVES.

GLEDHILL BOILERMATE 2000 DOMESTIC HOT WATER / PLATE HEAT EXCHANGER  PUMP RUNNING CONTINUOUSLY, REPAIRED AND LEFT RUNNING.

  

GLEDHILL BOILERMATE 2000 PCB.

 THE GT153 PHE SENSOR. SUGAR WAY, PETERBOROUGH

REPAIR GLEDHILL BOILERMATE FE AND TS MODELS [EARLY MODELS ]

COMMON FAULTS:

1.BRAWA-MIXING VALVE / SEIZED OR SCALED UP,THIS WILL GIVE UNSATISFACTORY HOT WATER OR NO HOT WATER.

2. PUMP FAILURE.

3.PUMP DELAY TIMER [ THIS WILL REMOVE ALL THE HOT WATER FROM THE BOILER PIPEWORK EACH TIME ITS SHUTS DOWN.

4.MECHANICAL/ DIGITAL TIME CLOCK FAILURE.

5. FEED AND EXPANSION TANK LEAKING INTO MAIN UNIT

[QUITE COMMON NOWDAYS ]

boilermate 11brawa mixing valve

GLEDHILL BOILERMATE 2000 REPAIRS, NO MAINS SUPPLY TO PCB, CUSTOMER HAD BEEN RUNNING ON "SWITCH" FACILLITY FOR 2 WEEKS. I FOUND THAT THE FUSE CARRIERS THAT CARRY THE FUSES FOR THE SWITCH HEATER BOTTLE WERE BURNT OUT AND 1 FUSE HAD POPPED, THIS TELLS ME THAT ONE OF THE 4.5KW HEATER COILS HAS FAILED, ALSO THE GLOWORM BOILER TO HEAT THE STORE WAS NOT FIRING UP. CUSTOMER TOLD ME THAT THEY HAD HAD 2 ENGINEERS TO LOOK AT THE BOILER AND HAD NOT BEEN ABLE TO RECTIFY THE FAULT, ONE OF THEM BEING FROM GLOWORM ! I FOUND THAT THE PCB CONTROL BOARD HAD BEEN REPLACED AND THE CONNECTION FOR THE AIR PRESSURE SWITCH WAS NOT MAKING A GOOD CONTACT, IT WAS ARCING AND CAUSING THE FAST BLOW FUSE ON THE BOILERMATE PCB TO POP.REMADE CONNECTION,REPLACED FUSE CARRIERS,AND GT153 SENSOR AS THIS WAS SHOWING ERROR CODE, LEFT IN WORKING ORDER, TO RETURN WITH SWITCH BOTTLE HEATER. ANOTHER HAPPY CUSTOMER. FERNDALE ESTATE, YAXLEY, PETERBOROUGH.

 gledhill boilermate 11 , customer complained that water was leaking around the bottom of his boilermate 11. found that the back up immersion heater had been leaking for sometime. as you can see there is extreme limescale damage to the immersion heater. drained down and replaced immersion heater , added inhibitor, refilled and tested. left in good working order. another happy customer !  RAVENSWOOD ESTATE, IPSWICH.

 gledhill electramate 2000 repairs, this one had no water in the thermal store, this had the supply to the backflow valve closed so the store was unable to replenish itself.customer said that there was a high pitched screaming coming from the cupboard, this turned out to be the heating pump, just before it ran dry and warped the drive shaft ! replaced pump head, refilled store to 1 bar and tested, all heating / hot water working fine.UPMINSTER, ESSEX.

THIS IS THE CLEANEST 12YR OLD BOILERMATE 2 I HAVE EVER SEEN !!!! ITS LIKE THE DAY IT WAS INSTALLED.




THE OVENTROP MIXER VALVE WAS SEIZED WITH LIMESCALE AND WAS GIVING NO HOT WATER AT THE TAP. REPLACED MIXER VALVE, ADDED FERNOX F1 TO STORE. TESTED, LEFT IN WORKING ORDER. ANOTHER HAPPY CUSTOMER.  METHWOLD, SUFFOLK.




gledhill boilermate 11, customer complained of a continual trickling sound coming from the unit. after intail inspection found that the store was only half full of water, found the cold feed from the expansion tank blocked as well as the open vent pipe ! which will not allow water into the store to replenish itself. removed tank and unblocked cold feed andopen vent pipe. refilled added fernox and left in working order. its quite rare to find both sides of the tank blocked.

cottenham,cambridgeshire.

  

REPAIR BOILERMATE FE /TS [EARLY BOILERMATE MODELS].